Product Code | Class EN1822 | Width (m) | Height (mm) | Depth (mm) | Spig Ot Diameter (m2) | Filtration Area (m2) | Nominal Air Flow (m3/h) | Initial Pressure Drop (± 10% Pa) |
HHF-13-A-305-305-Ø125-DG | H13 | 305 | 305 | 125 | Ø125 | 2,45 | 150 | 100 |
HHF-13-A-305-610-Ø150-DG | H13 | 305 | 610 | 125 | Ø150 | 4,90 | 300 | 100 |
HHF-13-A-457-457-Ø150-DG | H13 | 457 | 457 | 125 | Ø150 | 5,50 | 340 | 100 |
HHF-13-A-535-535-Ø200-DG | H13 | 535 | 535 | 125 | Ø200 | 7,55 | 465 | 100 |
HHF-13-A-575-575-Ø200-DG | H13 | 575 | 575 | 125 | Ø200 | 8,70 | 535 | 100 |
HHF-13-A-610-610-Ø200-DG | H13 | 610 | 610 | 125 | Ø200 | 9,80 | 600 | 100 |
HHF-13-A-610-762-Ø250-DG | H13 | 610 | 762 | 125 | Ø250 | 12,25 | 750 | 100 |
HHF-13-A-610-915-Ø250-DG | H13 | 610 | 915 | 125 | Ø250 | 14,70 | 900 | 100 |
HHF-13-A-610-1220-Ø250-DG | H13 | 610 | 1220 | 125 | Ø250 | 19,60 | 1200 | 100 |
HHF-14-A-305-305-Ø125-DG | H14 | 305 | 305 | 125 | Ø125 | 2,45 | 150 | 125 |
HHF-14-A-305-610-Ø150-DG | H14 | 305 | 610 | 125 | Ø150 | 4,90 | 300 | 125 |
HHF-14-A-457-457-Ø150-DG | H14 | 457 | 457 | 125 | Ø150 | 5,50 | 340 | 125 |
HHF-14-A-535-535-Ø200-DG | H14 | 535 | 535 | 125 | Ø200 | 7,55 | 465 | 125 |
HHF-14-A-575-575-Ø200-DG | H14 | 575 | 575 | 125 | Ø200 | 8,70 | 535 | 125 |
HHF-14-A-610-610-Ø200-DG | H14 | 610 | 610 | 125 | Ø200 | 9,80 | 600 | 125 |
HHF-14-A-610-762-Ø250-DG | H14 | 610 | 762 | 125 | Ø250 | 12,25 | 750 | 125 |
HHF-14-A-610-915-Ø250-DG | H14 | 610 | 915 | 125 | Ø250 | 14,70 | 900 | 125 |
HHF-14-A-610-1220-Ø250-DG | H14 | 610 | 1220 | 125 | Ø250 | 19,60 | 1200 | 125 |
Hooded HEPA Filters
Safe Air Hooded HEPA Filters deliver high-efficiency air purification for sensitive environments. The hood design enhances filtration efficiency by regulating airflow and is ideal for hospitals, labs, cleanrooms, and pharmaceutical production areas.
Applications of Hooded HEPA Filters
Safe Air Hooded HEPA Filters are used in cleanrooms, operating rooms, pharmaceutical facilities, and labs. The hood distributes airflow evenly across the filter surface, increasing efficiency and particle retention.
Advantages
- High Filtration Efficiency: Captures up to 99.97% of particles.
- Hood Design: Improves filtration by equalizing airflow.
- Energy Efficient: Low-pressure drop reduces energy costs.
- Durable Build: Ensures long-term use.
- Easy Installation: Integrates seamlessly with HVAC systems.
Choose Safe Air Hooded HEPA Filters for Clean and Safe Air!
For effective air purification in hygiene-critical areas, contact Safe Air for advanced Hooded HEPA filters.
Filter Media | Minipleat Micro Glass Fibre |
Frame Materia | Extruded Aluminium |
Classification (EN779) | E10 – U17 |
Gasket | Optional (Polyurethane / Epdm) |
Seperator | Hotmelt |
Sealant | 2K Polyurethane |
Final Pressure Drop | 600 Pa |
Max. Temperature | 80 °C |
Max. Moisture | 90% |
Product Code:
HHF-13-A-305-305-Ø125-DG
HHF-13-A-305-610-Ø150-DG
HHF-13-A-457-457-Ø150-DG
HHF-13-A-535-535-Ø200-DG
HHF-13-A-575-575-Ø200-DG
HHF-13-A-610-610-Ø200-DG
HHF-13-A-610-762-Ø250-DG
HHF-13-A-610-915-Ø250-DG
HHF-13-A-610-1220-Ø250-DG
HHF-14-A-305-305-Ø125-DG
HHF-14-A-305-610-Ø150-DG
HHF-14-A-457-457-Ø150-DG
HHF-14-A-535-535-Ø200-DG
HHF-14-A-575-575-Ø200-DG
HHF-14-A-610-610-Ø200-DG
HHF-14-A-610-762-Ø250-DG
HHF-14-A-610-915-Ø250-DG
HHF-14-A-610-1220-Ø250-DG