Product Code | Class EN1822 | Width (m) | Height (mm) | Depth (mm) | Spig Ot Diameter (m2) | Filtration Area (m2) | Nominal Air Flow (m3/h) | Initial Pressure Drop (± 10% Pa) |
HHF-13-A-305-305-Ø125-DG | H13 | 305 | 305 | 125 | Ø125 | 2,45 | 150 | 100 |
HHF-13-A-305-610-Ø150-DG | H13 | 305 | 610 | 125 | Ø150 | 4,90 | 300 | 100 |
HHF-13-A-457-457-Ø150-DG | H13 | 457 | 457 | 125 | Ø150 | 5,50 | 340 | 100 |
HHF-13-A-535-535-Ø200-DG | H13 | 535 | 535 | 125 | Ø200 | 7,55 | 465 | 100 |
HHF-13-A-575-575-Ø200-DG | H13 | 575 | 575 | 125 | Ø200 | 8,70 | 535 | 100 |
HHF-13-A-610-610-Ø200-DG | H13 | 610 | 610 | 125 | Ø200 | 9,80 | 600 | 100 |
HHF-13-A-610-762-Ø250-DG | H13 | 610 | 762 | 125 | Ø250 | 12,25 | 750 | 100 |
HHF-13-A-610-915-Ø250-DG | H13 | 610 | 915 | 125 | Ø250 | 14,70 | 900 | 100 |
HHF-13-A-610-1220-Ø250-DG | H13 | 610 | 1220 | 125 | Ø250 | 19,60 | 1200 | 100 |
HHF-14-A-305-305-Ø125-DG | H14 | 305 | 305 | 125 | Ø125 | 2,45 | 150 | 125 |
HHF-14-A-305-610-Ø150-DG | H14 | 305 | 610 | 125 | Ø150 | 4,90 | 300 | 125 |
HHF-14-A-457-457-Ø150-DG | H14 | 457 | 457 | 125 | Ø150 | 5,50 | 340 | 125 |
HHF-14-A-535-535-Ø200-DG | H14 | 535 | 535 | 125 | Ø200 | 7,55 | 465 | 125 |
HHF-14-A-575-575-Ø200-DG | H14 | 575 | 575 | 125 | Ø200 | 8,70 | 535 | 125 |
HHF-14-A-610-610-Ø200-DG | H14 | 610 | 610 | 125 | Ø200 | 9,80 | 600 | 125 |
HHF-14-A-610-762-Ø250-DG | H14 | 610 | 762 | 125 | Ø250 | 12,25 | 750 | 125 |
HHF-14-A-610-915-Ø250-DG | H14 | 610 | 915 | 125 | Ø250 | 14,70 | 900 | 125 |
HHF-14-A-610-1220-Ø250-DG | H14 | 610 | 1220 | 125 | Ø250 | 19,60 | 1200 | 125 |
Safe Air Hooded HEPA Filters deliver high-efficiency air purification for sensitive environments. The hood design enhances filtration efficiency by regulating airflow and is ideal for hospitals, labs, cleanrooms, and pharmaceutical production areas.
Safe Air Hooded HEPA Filters are used in cleanrooms, operating rooms, pharmaceutical facilities, and labs. The hood distributes airflow evenly across the filter surface, increasing efficiency and particle retention.
Choose Safe Air Hooded HEPA Filters for Clean and Safe Air!
For effective air purification in hygiene-critical areas, contact Safe Air for advanced Hooded HEPA filters.
Filter Media | Minipleat Micro Glass Fibre |
Frame Materia | Extruded Aluminium |
Classification (EN779) | E10 – U17 |
Gasket | Optional (Polyurethane / Epdm) |
Seperator | Hotmelt |
Sealant | 2K Polyurethane |
Final Pressure Drop | 600 Pa |
Max. Temperature | 80 °C |
Max. Moisture | 90% |
Product Code:
HHF-13-A-305-305-Ø125-DG
HHF-13-A-305-610-Ø150-DG
HHF-13-A-457-457-Ø150-DG
HHF-13-A-535-535-Ø200-DG
HHF-13-A-575-575-Ø200-DG
HHF-13-A-610-610-Ø200-DG
HHF-13-A-610-762-Ø250-DG
HHF-13-A-610-915-Ø250-DG
HHF-13-A-610-1220-Ø250-DG
HHF-14-A-305-305-Ø125-DG
HHF-14-A-305-610-Ø150-DG
HHF-14-A-457-457-Ø150-DG
HHF-14-A-535-535-Ø200-DG
HHF-14-A-575-575-Ø200-DG
HHF-14-A-610-610-Ø200-DG
HHF-14-A-610-762-Ø250-DG
HHF-14-A-610-915-Ø250-DG
HHF-14-A-610-1220-Ø250-DG